Properties
-
Rugged stainless steel case
-
Integral magnetic base with a contact for VMID* data readout in its center
-
Double shielding for best EMI protection
-
M12 connector for easier assembly in spite of protection grade IP67
* VMID measuring points are coupling parts made of magnetic stainless steel which contain a unique digital serial number. It is read by a contact in the sensor base and transmitted via the sensor cable to a VMID compatible instrument. VMID simplifies measurements at a large number of points and helps to manage measuring routes. Please contact Metra for support when you are interested in designing your own VMID instruments.
Linear frequency range :
-
f3 dB : 0,2 .. 14000 Hz
-
f10 % : 0,4 .. 10000 Hz
-
f5 % : 0,6 .. 7500 Hz
Resonant frequency fr > 20 (+25 dB) kHz
Operating temperature range Tmin/Tmax : -30 / 100 °C
|