OPASTOP GP2001H Dust concentration emissions measuring

CHARACTERISTICS

  • Power supply :   230 V ~ / 115 V ~ (+10/-15%) 50 Hz / 60 Hz
  • Power consumption :   400VA (with scanner head heater)
  • Operating temperature :   -20 to +50°C
  • Measuring range :   0 to 1000 mg/Nm3
  • Measuring scale adjustable, minimum : 50 mg/Nm3
  • Display correction : from 0.1 to 1 mg/Nm3 according to scale
  • Twin measuring scale 
  • Analogue output :   4-20 mA for 750 Ohms (adjustable for 0-24 mA) with possibility of fault display
  • Digital processing :  3 programmable relays on scale, threshold and general fault
  • Warranty 1 year
  • Admissable temperature on fibres -20 to 220°C

Options / Services

  • High temperature scanner head (475°C)
  • Stainless steel 304L housing
  • Sized fibre optic length
  • Commissioning assistance
  • Maintenance contract
  • Optional 3 year warranty

 

 